DIN21.STATE to DIN32.STATE
Description
DIN21.STATE to DIN32.STATE reads the state of one digital input according to the number identified in the command.
General Information
Type |
R/O Parameter |
Units |
N/A |
Range |
0 to 1 |
Default Value |
N/A |
Data Type |
Integer |
Start Version |
M_01-00-00-000 |
Variants Supported
Supported by any AKD with extended IO.
Fieldbus Information
If your drive type is listed as supported but no index, address, or instance number is listed, then this parameter is accessible through WorkBench, but not over your fieldbus type.
Parameter | Fieldbus | Address | Attributes | Signed? |
---|---|---|---|---|
DIN21.STATE |
PROFINET |
2660 | Byte | No |
Sercos® III | 2 Octets | |||
DIN22.STATE |
PROFINET |
2666 | Byte | |
Sercos® III | 2 Octets | |||
DIN23.STATE |
PROFINET |
2672 | Byte | |
Sercos® III | 2 Octets | |||
DIN24.STATE |
PROFINET |
2678 | Byte | |
Sercos® III | 2 Octets | |||
DIN25.STATE |
PROFINET |
2684 | Byte | |
Sercos® III | 2 Octets | |||
DIN26.STATE |
PROFINET |
2690 | Byte | |
Sercos® III | 2 Octets | |||
DIN27.STATE |
PROFINET |
2696 | Byte | |
Sercos® III | 2 Octets | |||
DIN28.STATE |
PROFINET |
2702 | Byte | |
Sercos® III | 2 Octets | |||
DIN29.STATE |
PROFINET |
2708 | Byte | |
Sercos® III | 2 Octets | |||
DIN30.STATE |
PROFINET |
2714 | Byte | |
Sercos® III | 2 Octets | |||
DIN31.STATE |
PROFINET |
2720 | Byte | |
Sercos® III | 2 Octets | |||
DIN32.STATE |
PROFINET |
2726 | Byte | |
Sercos® III | 2 Octets |
Parameter | Register Address | Is 64 bit? | Attributes | Signed? |
---|---|---|---|---|
DIN21.STATE | 1320 | No | 8 bit | No |
DIN22.STATE | 1332 | |||
DIN23.STATE | 1344 | |||
DIN24.STATE | 1356 | |||
DIN25.STATE | 1368 | |||
DIN26.STATE | 1380 | |||
DIN27.STATE | 1392 | |||
DIN28.STATE | 1404 | |||
DIN29.STATE | 1416 | |||
DIN30.STATE | 1428 | |||
DIN31.STATE | 1440 | |||
DIN32.STATE | 1452 |